Skip to content
Draft
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
11 changes: 11 additions & 0 deletions ebusd-2.1.x/en/vaillant/15.vai00.csv
Original file line number Diff line number Diff line change
@@ -0,0 +1,11 @@
# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment
#,recov,RecoVair 275,,,,,,,,,,,
*r,,,,,,B509,0D,,,,,,
*w,,,,,,B509,0F,,,,,,
Copy link
Owner

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

this seems to be wrong and should rather be 0E instead of 0F.
please check

*wi,#install,,,,,B509,0F,,,,,,
# ##### general #####,,,,,,,,,,,,,
r;w,,VentMode,,,,,2400,,,UCH,1=Day;2=Out;3=Auto;5=Night,,
r;w,,VentHI,Wietrzenie,,,,5800,,,BCD:2,,,
r;w,,Waermerueckgewinnung,Waermerueckgewinnung,,,,0a00,,,UCH,1=An;2=Aus,,,,
r,,Waermerueckgewinnung_Tage,Waermerueckgewinnung_Tage,,,,3600,,,,,,,,
r,,Time,,,,,2C00,,,VTI,,,
19 changes: 19 additions & 0 deletions ebusd-2.1.x/en/vaillant/c0.wtw04.csv
Original file line number Diff line number Diff line change
@@ -0,0 +1,19 @@
# type (r[1-9] w u ),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment
#,recov,RecoVair 275,,,,,,,,,,,
# ########### general ################,,,,,,,,,,,,,
*r,,,,,,B509,0D,,,,,,
*w,,,,,,B509,0E,,,,,,
r;w,,BypassValve,,,,,0a00,,,onoff,,,
r;w,,FrostProtection,,,,,4700,,,onoff,,,
r;w,,FlowCorrection,Set volume flow correction,,,,2000,,,D1B,,,
r;w,,room_temperature,,,,,0000,,,temp,,,
w,,ventilation,ventilation level,,,,1500,,,UIN,,m³/h, wartosc do wymnozenia przez 3/10
#r,,VolumeFlowAct,,,,,1500,,,UIN,,,
####### #####,,,,,,,,,,,,,
*r,,,,,,B509,29,,,IGN:2,,,
*w,,,,,,B509,,,,,,,
Copy link
Owner

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

those writes can't work that way as it should read "B509,0E" instead

r;w,,SAI_temperature,Supply air temperature,,,,0100,,,temp,,,
r;w,,SAO_temperature,Outside air temperature,,,,0200,,,temp,,,
r;w,,EAI_temperature,Exhaust air temperature,,,,0300,,,temp,,,
r;w,,EAO_temperature,Extract air temperature,,,,0400,,,temp,,,
r;w,,YieldTotal,,,,,4d00,,,UIN,,kWh,